| MFR / Brand | Allen Bradley |
|---|---|
| MPN | 22A-D2P3N104 |
| Model | PowerFlex 4 |
| Number Of Phases | 3 |
|---|---|
| Input Voltage | 380-480 V AC 3-phase (340-528 V range) |
| Rated Power | 1 hp |
| Type | AC Drive |
| Output Current | 2.3 A continuous |
| Industry Terms | AC drive; variable frequency drive; VFD; adjustable frequency drive; compact AC drive; PowerFlex 4; 480 V 3-phase drive |
| Common Misspellings | 22A-D2P3N1O4; 22AD2P3N1O4; 22A-D2P3NI04; 22A-D2P3M104 |
| Application Types | Speed control of three-phase AC motors up to 0.75 kW (1 HP) |
| Output Voltage | 0-460 V AC 3-phase (label) |
| Mpn Variants | 22A-D2P3N104; 22AD2P3N104; 22A D2P3N104 |
| Manufacturer Status | Discontinued June 30, 2025 (Rockwell) |
| Compatible With Replaces | Rockwell replacement 25A-D2P3N104 (PowerFlex 523); flange-mount version 22A-D2P3F104 |
| Additional Attributes | Frame: A; input 2.3 kVA, 3.2 A, 340-528 V range; overload 150% 60 s / 200% 3 s (Class 10); efficiency 97.5% typical; carrier 2-16 kHz (rating at 4 kHz); watts loss 40 W total; recommended fuse 6 A; ambient -10 to 40 °C (Option A / IP30 kit), to 50 °C (Option B, IP20 open); storage -40 to +85 °C; altitude 1,000 m without derating; humidity 0-95% non-condensing; bus overvoltage trip 810 V DC; undervoltage trip 390 V DC; HIM fixed keypad; no EMC filter; certifications UL508C, CSA 22.2 No. 14, CE; Rockwell ship weight 1.4 kg (3.1 lb); label: Series A, FRN 6.01, 2013 |
| Series | PowerFlex 4 |
| Ip Rating | IP20 / NEMA Type Open |
| Part Number | 22A-D2P3N104 |
| Mounting Type | Panel mount (screws or 35 mm DIN rail) |
| Power Kw | 0.75 kW |
| Communication Standard | RS-485 (DSI) |
| Output Frequency | 0-240 Hz programmable |
| Cross Reference 1 | Allen-Bradley 25A-D2P3N104 - PowerFlex 523, Rockwell replacement |
|---|---|
| Cross Reference 2 | Allen-Bradley 22A-D2P3F104 - flange mount version |
| Cross Reference 3 | Allen-Bradley 22B-D2P3N104 - PowerFlex 40, same 2.3 A / 1 HP |
Allen-Bradley 22A-D2P3N104 is a PowerFlex 4 AC drive rated 0.75 kW (1 HP), 2.3 A, for 380–480 V AC three-phase input: Frame A, panel mount, IP20 (NEMA/UL Type Open), with integral RS-485 communication. Unit Quantity: 1 Pc. Condition: used. This unit is the drive power section only: the front cover with the keypad/display and the control I/O are not included. Label: Series A, FRN 6.01, manufactured 2013. Country of origin: China.
22A — Drive: PowerFlex 4.
D — Voltage rating: 480 V AC, three-phase.
2P3 — Rating: 2.3 A, 0.75 kW (1.0 HP), 380–480 V input.
N — Enclosure: panel mount, IP20.
1 — HIM: fixed keypad.
0 — Emission class: not filtered.
4 — Type: standard (code 3 is the no-brake-IGBT type).
Drive Family: PowerFlex 4 (Bulletin 22A). Motor Rating: 0.75 kW (1 HP). Input: 380–480 V AC three-phase, 340–528 V range, 2.3 kVA, 3.2 A; 48–63 Hz (label). Output Current: 2.3 A continuous. Output Frequency: 0–240 Hz, programmable. Output Voltage: 0–460 V AC three-phase (label). Overload: 150% for 60 seconds, 200% for 3 seconds, Class 10 motor protection (label: 3.45 A for 60 s). Efficiency: 97.5% typical. Carrier Frequency: 2–16 kHz, drive rating based on 4 kHz. Watts Loss: 40 W total. Frame: A. Recommended Branch Fuse: 6 A. Communications: integral RS-485 (DSI). Ambient Operating Temperature: −10 to 40 °C (14 to 104 °F) IP20/open type with Mounting Option A or IP30/NEMA 1 kit; up to 50 °C (122 °F) IP20/open type with Mounting Option B. Storage Temperature: −40 to +85 °C (−40 to +185 °F). Altitude: 1,000 m (3,300 ft) without derating. Relative Humidity: 0–95%, non-condensing. Bus Overvoltage Trip: 810 V DC. Bus Undervoltage Trip: 390 V DC. Certifications: UL508C, CSA 22.2 No. 14, CE. Firmware: FRN 6.01 (label). Rockwell lifecycle status: Discontinued June 30, 2025.
Frame A drive. Mounts upright on a flat, vertical surface with M4 (#8-32) screws, torque 1.56–1.96 N·m (14–17 lb·in), panel 1.9 mm minimum, or on 35 mm DIN rail. Rockwell shipping weight: 1.4 kg (3.1 lb).
Rockwell lists the PowerFlex 523 25A-D2P3N104 as the engineering replacement. The flange-mount version of this drive is 22A-D2P3F104. The PowerFlex 40 with the same 2.3 A / 1 HP rating is 22B-D2P3N104. Also written 22AD2P3N104.
Three-phase motors up to 0.75 kW (1 HP) on 380–480 V AC, with 2.3 A continuous output current.
The drive power section only. The front cover with the keypad/display and the control I/O are not included.
Rockwell lists the PowerFlex 523 25A-D2P3N104 as the engineering replacement; the PowerFlex 4 was discontinued June 30, 2025.
$195.99
4 in stock
$396.99
4 in stock
$455.99
5 in stock
$130.99
4 in stock
$144.99
4 in stock
$161.99
5 in stock
$125.99
1 in stock
$290.99
16 in stock
Many industrial loads need torque an electric motor can’t deliver on its own, at a
Belt drives may appear simple, consisting of two wheels and a belt for power transfer.
Tapered, cylindrical, and spherical roller bearings all solve the same basic problem, carrying more load
Our team can locate, cross-reference, and source all parts.
Our team can locate, cross-reference, and source all parts.
Sort
Brand
Price
MPN
Categories