New Inventory Daily | Same Day Free Shipping

13k+ reviews

Stahl9146/10-11-12Ex i Frequency Transmitter — 1 Channel, NAMUR Input, 0/4-20 mA Output, 2 Limit Contacts, Pulse Output, 24 V DC

Condition: Used

Availability:

1 in stock

R. Stahl 9146/10-11-12 single-channel Ex i frequency transmitter, NAMUR input to 0/4-20 mA output with 2 limit contacts and pulse output, 24 V DC, DIN rail.

List Price

$135.96

1 in stock

Prefer eBay? Buy this item on our store (opens in a new tab)

Small green outline icon of a shipping box with a clock, indicating delivery time
Availability

1 in stock

On the Shelf & Ready to Ship

Green shield badge reading "Same-Day Shipping" with box and delivery truck icons
Free Shipping

On all orders

Green shield icon with box and arrow graphic labeled "Free Returns"
Free Returns

No Risk, No Hassle

Specifications

Key Specifications

MFR / BrandStahl
MPN9146/10-11-12
Model9146/10-11-12

Technical Specifications

TypeFrequency Transmitter
Additional AttributesChannels: 1; Input: NAMUR EN 60947-5-6, 0.001-20,000 Hz; Output: 0/4-20 mA, load 0-600 ohm; Limit contacts: 2 NO electronic 30 V / 50 mA; Pulse output: 0-5 kHz, 1:1 to 1:20,000; Power: 24 V DC, 55 mA, 1.32 W; Enclosure: IP30; Width: 17.6 mm; Ambient: -40 to +70 C; ATEX II 3 (1) G Ex nAc nCc [ia] IIC T4
Item Weight160 g (0.35 lb)
Base Number9146
Industry TermsEx i isolator; intrinsically safe barrier; frequency to current converter; speed monitor; NAMUR isolator; IS interface
Common MisspellingsStal 9146; R.Stahl 9146 10 11 12; 9146/10-11-21; frequency transmiter
Application TypesSpeed monitoring of fans, centrifuges, blades and stirrers in hazardous areas; oil and gas; chemical plant; marine
Mpn Variants9146/10-11-12; 9146101112; 9146-10-11-12; 9146/10-11-12s; 9146/10-11-12k
Compatible With ReplacesCurrent order codes 9146/10-11-12s (screw terminals) and 9146/10-11-12k (spring clamp terminals)
Series9146
Nominal Rated Input Voltage24 V DC (18 to 31.2 V)
Mounting TypeDIN rail NS35 or pac-Carrier
Seller Part Number: AQ1B4#FIYP0Z

Product Description

What this part is:

The R. Stahl 9146/10-11-12 is a single-channel frequency transmitter from the ISpac Series 9146 Ex i isolators. It converts an intrinsically safe binary input from a hazardous-area sensor into a 0/4–20 mA signal proportional to frequency, with two limit value contacts and a pulse output. Typical duty is speed monitoring of fans, centrifuges, blades and stirrers in hazardous areas.

Decoding the designation:

9146 — R. Stahl Series 9146 frequency transmitter, Ex i field circuit.

10-11-12 — the 1-channel version with 0/4–20 mA output, 2 NO/NC limit value contacts and one selectable NO impulse output.

Specifications:

Channels: 1. Input Signal: NAMUR per EN 60947-5-6. Input Frequency: 0.001 to 20,000 Hz. Output Signal: 0/4 to 20 mA, configurable. Connectable Load: 0 to 600 Ω. Limit Value Contacts: 2 NO (electronic), ±30 V, 50 mA. Pulse Output: 0 to 5 kHz, dividing ratio 1:1 to 1:20,000. Auxiliary Power: 24 V DC nominal, 18 to 31.2 V range. Nominal Current: 55 mA. Power Consumption: 1.32 W. Accuracy: 0.1 % typical. Parameterisation: ISpac Wizard software.

Explosion Protection: ATEX II 3 (1) G Ex nAc nCc [ia] IIC T4; II (1) D [Ex ia] IIIC; IECEx Ex nA nC [ia Ga] IIC T4 Gc. Installation: Zone 2, Division 2 and safe area, with the Ex i field circuit reaching Zone 0 and Division 1.

Dimensions and mounting:

Mounting: DIN rail NS35/15 or NS35/7.5, or pac-Carrier. Width: 17.6 mm. Enclosure: IP30, PA 6.6. Terminals: IP20. Ambient Temperature: -40 to +70 °C single device; -20 to +60 °C group assembly. Item Weight: approx. 160 g.

Compatibility and replacement:

Current order codes add a terminal suffix: 9146/10-11-12s for screw terminals, 9146/10-11-12k for spring clamp terminals. The 2-channel 9146/20-11-11 has no limit contacts or pulse output.

Frequently asked questions:

What input does the 9146/10-11-12 accept?

A NAMUR input per EN 60947-5-6, 0.001 to 20,000 Hz.

What are the output signals?

A 0/4 to 20 mA analog output into 0 to 600 Ω, two electronic NO limit contacts and a 0 to 5 kHz pulse output.

What power does it need?

24 V DC nominal, 18 to 31.2 V range, 55 mA nominal current.

You May Also Like

Siemens 6FX1121-4BA01 servo interface module – image 1
6FX1121-4BA01

$137.67

4 in stock

Add to cart
RAYCON 302224 power switch board – image 1
302224

$417.66

4 in stock

Add to cart
GE Fanuc IC610MDL154A output module – image 1
IC610MDL154A

$76.11

7 in stock

Add to cart

Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Assortment of MRO parts including motor, bearing, gears, cylinder and valve

News

Pillow Block Replacement: How to Match It Right

Learn what a pillow block bearing is, how to size

Tapered Bearings: Guide, Sizing & Where to Buy

Tapered bearings explained: types, sizing, preload, and how to find

Additional Resources

Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Get In Touch
Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Get In Touch

Sort

Brand

Price

MPN

Categories

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.