50,000+ Bearings | 50-90% Under Distributor Price | Same Day Free Shipping

13k+ reviews 99.9% positive eBay feedback · 2,336 ratings in the last 12 months

FACTS EngineeringF3-08TRS-2DL305 8-Point Relay Output Module, 6 Form A + 2 Form C, Isolated Commons

Condition: New – Open box

Availability:

1 in stock

FACTS Engineering F3-08TRS-2 DL305 relay output module, 8 points: 6 Form A + 2 Form C, 8 isolated commons, 12-250 V AC / 12-30 V DC, 4 A/point. New old stock.

Same day shipment

List Price

$23.79

1 in stock

Prefer eBay? Buy this item on our store (opens in a new tab)

Small green outline icon of a shipping box with a clock, indicating delivery time
Availability

1 in stock

On the Shelf & Ready to Ship

Green shield badge reading "Same-Day Shipping" with box and delivery truck icons
Free US Shipping

Ships same day by 6pm ET

Green shield icon with box and arrow graphic labeled "Free Returns"
Free Returns

No Risk, No Hassle

Specifications

Key Specifications

MFR / BrandFACTS Engineering
MPNF3-08TRS-2
ModelF3-08TRS-2

Technical Specifications

Analog DigitalDigital
TypeRelay Output Module
Industry Termsrelay output module; PLC output module; isolated relay output; discrete I/O module; DL305 I/O; DirectLOGIC 305
Common MisspellingsF3-O8TRS-2; F308TRS-2; F3-08TSR-2; F3-08TRS-Z; F3-08RTS-2
Application TypesSwitching AC or DC loads from a DL305 PLC: contactors, solenoids, pilot lights, motor starters
Output TypeRelay: 6 Form A (SPST) + 2 Form C (SPDT)
Controller PlatformDL305
Current Rating4 A/point resistive AC/DC; 32 A/module
Output Voltage12-250 V AC; 12-30 V DC
Mpn VariantsF3-08TRS-2; F308TRS2; F3 08TRS 2; F3-08TRS2
Manufacturer StatusActive (in stock at AutomationDirect)
Compatible With ReplacesDirectLOGIC DL305 bases (e.g. D3-05BDC, D3-10BDC); same family F3-08TRS-1
Additional AttributesCommons: 8 isolated (1 point per common); peak voltage 265 V AC / 120 V DC (120 V DC at 0.5 A, 30,000 cycles typical); max inrush 10 A inductive; minimum load 100 mA at 12 V DC; base power 9 V DC, 37 mA per ON point (296 mA max); no external 24 V supply; fuses 8 x 10 A 125 V replaceable; status indicators logic side; removable terminal block; mechanical life 100 million operations; ZIPLink derating 2 A/point, 4 A/common; weight 9 oz (255 g); UL file E139594; label: June 1999 date stamp, CE
SeriesDL305
Part NumberF3-08TRS-2
Contact Configuration6 Form A (SPST) + 2 Form C (SPDT)

Cross-References

Cross Reference 1FACTS F3-08TRS-1 - -1 version, not ZIPLink supported
Seller Part Number: AQ1B1#FXGHJI

Product Description

What this part is:

FACTS Engineering F3-08TRS-2 is an 8-point relay output module for the DL305 (DirectLOGIC 305) PLC system: 6 Form A (SPST) and 2 Form C (SPDT) outputs, 8 isolated commons (1 point per common), a replaceable fuse on each output and a removable terminal block. Unit Quantity: 1 Pc. Condition: new old stock, opened box. Label: June 1999 date stamp, CE marked. Country of origin: USA.

Decoding the designation:

F3-08TRS-2 — FACTS Engineering DL305 8-point isolated relay output module, -2 version. The -1 version is F3-08TRS-1.

Specifications:

Outputs Per Module: 8. Output Type: 6 Form A (SPST), 2 Form C (SPDT), no suppression. Commons: 8, isolated. Operating Voltage: 12–250 V AC, 12–30 V DC. Peak Voltage: 265 V AC / 120 V DC (120 V DC rating at 0.5 A, 30,000 cycles typical). Maximum Current (Resistive): 4 A per point AC/DC, 32 A per module. Maximum Inrush Current: 10 A inductive. Minimum Load: 100 mA at 12 V DC. OFF to ON Response: 13 ms max. ON to OFF Response: 9 ms max. Base Power Required: 9 V DC, 37 mA per ON point (296 mA max); no external 24 V DC supply. Fuses: 8 fuses (10 A, 125 V), replaceable. Status Indicators: logic side. Terminal Type: removable. Expected Mechanical Relay Life: 100 million operations. ZIPLink Wiring: outputs derated to 2 A per point and 4 A per common. Weight: 9 oz (255 g). Listing: UL file E139594. Marking: CE (label).

Dimensions and mounting:

Installs in a DL305 base I/O slot (the data sheet power tables reference the D3-05BDC and D3-10BDC bases), with a removable field-wiring terminal block. Weight: 9 oz (255 g).

Compatibility and replacement:

For DirectLOGIC DL305 PLC systems, sold through AutomationDirect. Same family: F3-08TRS-1, which is not supported by the ZIPLink wiring system. Also written F308TRS2.

Frequently asked questions:

What outputs does the F3-08TRS-2 have?

8 relay outputs: 6 Form A (SPST) and 2 Form C (SPDT), each on its own isolated common with a replaceable 10 A, 125 V fuse.

What load voltage and current can it switch?

12–250 V AC or 12–30 V DC, 4 A per point resistive and 32 A per module. Peak voltage is 265 V AC / 120 V DC.

Which PLC system does it work with?

The DL305 (DirectLOGIC 305) system; it plugs into a DL305 base I/O slot and draws 9 V DC base power.

You May Also Like

Siemens 6SC6100-0GE01 Power Supply Infeed Module – image 1
6SC6100-0GE01

$1,224.99

5 in stock

Add to cart
Captron C0A-1A-6G5/Q44T-PS3 capacitive level probe – image 1
C0A-1A-6G5/Q44T-PS3

$100.99

15 in stock

Add to cart
AEG 1S-400-30-HRL1 thyristor power controller – image 1
1S-400-30-HRL1

$290.99

16 in stock

Add to cart

Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Assortment of MRO parts including motor, bearing, gears, cylinder and valve

News

Plant Closing? Sell the Bearing Crib Before the Auction

What to do with surplus bearings from a plant closure:

Read the Series Letter: Industrial Automation Part Numbers

How to read industrial automation part numbers on Allen-Bradley, Fanuc

Additional Resources

Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Get In Touch
Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Get In Touch

Sort

Brand

Price

MPN

Categories

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.