New Inventory Daily | Same Day Free Shipping

13k+ reviews

EatonFAZ-D10/3UL 1077 Supplementary Protector – 10 A, Three-Pole, D Curve, 15 kAIC, DIN Rail

Condition: New

Availability:

1 in stock

UL 1077 supplementary protector, 10 A, three-pole, D curve for high inrush, 15 kAIC interrupting, 50–60 Hz, DIN rail mount, standard screw terminals.

List Price

$66.47

1 in stock

Prefer eBay? Buy this item on our store (opens in a new tab)

Small green outline icon of a shipping box with a clock, indicating delivery time
Availability

1 in stock

On the Shelf & Ready to Ship

Green shield badge reading "Same-Day Shipping" with box and delivery truck icons
Free Shipping

On all orders

Green shield icon with box and arrow graphic labeled "Free Returns"
Free Returns

No Risk, No Hassle

Specifications

Key Specifications

MFR / BrandEaton
MPNFAZ-D10/3
GTIN4015082788926
ModelFAZD10/3

Technical Specifications

TypeCircuit Breakers - Supplementary Protector
Base NumberFAZ
Industry TermsMiniature circuit breaker, MCB, supplementary protector, DIN rail breaker, motor circuit protector, three-pole breaker, D curve breaker
Common MisspellingsEaton Cutler Hammer, Cutler-Hammer, Klockner Moeller, Kloeckner Moeller, Moeller FAZ, FAZ D 10/3, FAZD10-3
Application TypesMotor branch protection in control panels, transformer primary protection, high-inrush inductive loads, machine tool control cabinets, HVAC equipment panels
Number Of PolesThree-pole
Output Amperage10 A
Mpn VariantsFAZ-D10/3, FAZD10/3, FAZ D10/3, FAZ-D10-3, FAZ D10 3, FAZD103
SeriesFAZ cable-in cable-out
Part NumberFAZ-D10/3
Mounting Type35 mm DIN rail, snap-on
Seller Part Number: AL3B4#F4YOUA

Product Description

What this part is: Eaton FAZ-D10/3, an industrial miniature circuit breaker classed as a UL 1077 supplementary protector. Series: FAZ cable-in cable-out. Product Type: Supplementary protector. Amperage Rating: 10 A. Number Of Poles: Three-pole. Trip Curve: D. Trip Type: 10–20 × In. Interrupting Rating: 15 kAIC. Frequency: 50–60 Hz. Terminals: Standard. Mounting: DIN rail. GTIN: 4015082788926. Country of Origin: Romania. What the D curve buys: Trip Curve: D. Trip Type: 10–20 × In — the magnetic element holds off until the current reaches ten to twenty times the 10 A rating, so on this device between 100 A and 200 A. That magnetic band is set high on purpose, to ride through the startup inrush of motors, transformers and other strongly inductive loads without nuisance tripping, while the thermal element still protects the conductor against sustained overload. A B or C curve on the same 10 A frame trips in a much lower magnetic band and would drop out on the same motor start. Ratings and standards: Amperage Rating: 10 A. Interrupting Rating: 15 kAIC. Frequency: 50–60 Hz. Number Of Poles: Three-pole, common trip across the three poles on a single toggle. Certifications: UL 1077, CSA Standard C22.2 No. 235, IEC 60947-2. The UL 1077 listing classes this as a supplementary protector for use inside equipment downstream of branch-circuit protection, which is the standard duty for a control-panel motor or transformer circuit on an industrial machine. Mounting and wiring: Mounting: 35 mm DIN rail, snap-on. Terminals: Standard screw terminals. Frame: Cable-in cable-out, so line and load both land on screw terminals rather than on a busbar comb. The FAZ frame is reverse-feed capable, meaning line and load can be taken on either end without derating, and the mechanism is trip-free so the toggle cannot be held closed onto a fault. Quantity and configuration: Unit Quantity: 1 Pc. Supplied as one three-pole device on a common trip bar, complete with its toggle and screw terminals. Interchange guidance: FAZ-D10/3-NA is the related North American execution of this same 10 A, three-pole, D-curve frame, listed to UL 489 as a branch-circuit breaker at 10 kA on 480Y/277 VAC rather than to UL 1077 as a supplementary protector. The two carry different listings and different interrupting figures, so the -NA is a related part and not a drop-in equivalent. Searchable variants of this designation: FAZ-D10/3, FAZD10/3, FAZ D10/3, FAZ-D10-3, FAZ D10 3, and the older Klöckner-Moeller FAZ nomenclature.

You May Also Like

3-Pole Motor-Protective Circuit-Breaker / Manual Motor Starter, 0.16-0.24 A Adjustable, 690 V, DIN Rail
PKZM0,24

$32.17

2 in stock

Add to cart
Servo Drive Control PCB, Board A16B-1200-0742 Revision 05C
A06B-6061-J004

$114.73

1 in stock

Add to cart
Miniature Circuit Breaker — 20 A, 3 Pole, D Curve, 10 kA, 400 V AC

$38.22

3 in stock

Add to cart

Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Assortment of MRO parts including motor, bearing, gears, cylinder and valve

News

Selling an MRO Storeroom in One Lot

Most plants clear a storeroom one part number at a

Selling Surplus Fanuc Boards and Servo Amplifiers

When a CNC machine or a robot leaves the plant,

Additional Resources

Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Get In Touch
Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Get In Touch

Sort

Brand

Price

MPN

Categories

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.