Reliance Electric 1SU44001 SP500 AC drive, 1 HP, 380-460 V AC 3-phase, 2.1 A output, NEMA 4X/12 enclosure with keypad. Used; cover cracked at one corner.
List Price
$195.49

1 in stock
On the Shelf & Ready to Ship
Ships same day by 6pm ET

No Risk, No Hassle
| MFR / Brand | Reliance Electric |
|---|---|
| MPN | 1SU44001 |
| Model | SP500 |
| Number Of Phases | 3 |
|---|---|
| Input Voltage | 380-460 V AC 3-phase, 2.5 A |
| Industry Terms | AC drive; variable frequency drive; VFD; adjustable speed drive; washdown drive; NEMA 4X drive; SP500 |
| Common Misspellings | 1SU4401; ISU44001; 15U44001; 1SU44OO1; 1SU-4401; SP-500 1SU44001 |
| Application Types | Speed control of 1 HP three-phase AC motors on 380-460 V AC |
| Rated Power | 1 hp |
| Output Voltage | 380-460 V AC 3-phase (label) |
| Mpn Variants | 1SU44001; 1SU-44001; 1SU 44001 |
| Compatible With Replaces | Same rating in NEMA 1 vented enclosure: 1SU41001 |
| Additional Attributes | Enclosure size: B; input 2.5 A, 2.0 kVA; output 2.1 A; watts loss 60 W; overload 150% for 1 min; ride-through 500 ms; carrier 4/6/8 kHz selectable; storage -40 to +65 °C; humidity 5-95% non-condensing; altitude derate 1% per 91.4 m above 1,000 m; protection overcurrent, short circuit, ground fault, overvoltage, undervoltage, overtemperature; analog reference 0-10 V DC or 0-20 mA; analog output 0-10 V DC; relay output terminals 14-16; snubber braking terminals 12-13; 4-character LED display, 6 membrane keys; mounting 4 x M8 (5/16 in) bolts; Reliance manual D2-3356-6; label: 50/60 Hz, Type 4X indoor use only, UL listed, CE |
| Series | SP500 |
| Part Number | 1SU44001 |
| Mounting Type | Bolt mount, four M8 (5/16 in) bolts |
| Output Frequency | 0.5-240 Hz |
| Output Current | 2.1 A |
| Cross Reference 1 | Reliance Electric 1SU41001 - NEMA 1 vented enclosure version |
|---|
Reliance Electric 1SU44001 is an SP500 AC drive rated 1 HP for 380–460 V AC three-phase input, enclosure size B, in a NEMA 4X/12 enclosure (not vented; water-tight and dust-tight) with a built-in keypad and LED display. Unit Quantity: 1 Pc. Condition: used; the cover is cracked at one corner. Label: Type 4X, indoor use only; UL listed, CE.
1SU4 — SP500 model range for 380–460 V AC input (1SU1 = 115 V AC, 1SU2 = 208–230 V AC, 1SU5 = 575 V AC).
1SU44001 — In the Reliance model table, the 1 HP, NEMA 4X/12, enclosure B model. The NEMA 1 version of the same rating is 1SU41001.
Power: 1 HP. Input: 380–460 V AC three-phase, 2.5 A, 2.0 kVA; 50/60 Hz (label). Output Current: 2.1 A. Output Frequency: 0.5–240 Hz (label: 0–240 Hz). Output Voltage: 380–460 V AC three-phase (label). Watts Loss: 60 W. Overload: 150% for one minute. Power Dip Ride-Through: 500 ms. Carrier Frequency: 4, 6 or 8 kHz, user selectable. Ambient Operating Temperature: 0 to 40 °C (32 to 104 °F). Storage Temperature: −40 to +65 °C (−40 to +149 °F). Relative Humidity: 5–95%, non-condensing. Altitude: above 1,000 m, output current derates 1% per 91.4 m (300 ft). Protection: overcurrent, short circuit, ground fault, overvoltage, undervoltage, overtemperature; UL/CSA electronic motor overload. Display: four-character seven-segment LED with RUN, PROGRAM, FORWARD, REVERSE, REMOTE, RPM/engineering unit, %LOAD and VOLTS LEDs. Keypad: six membrane keys (MODE/ENTER, UP, DOWN, FORWARD/REVERSE, START, STOP/RESET). Analog Speed Reference: 0–10 V DC or 0–20 mA, jumper J6 selected. Analog Output: 0–10 V DC, proportional to speed, load, output voltage or selected reference. Digital Inputs: terminals 6–11 (stop, start, IET reset, forward/reverse, function loss), 24 V DC unregulated supply. Braking: snubber resistor connections on terminals 12–13. Relay Output: terminals 14–16, selectable by F-09 for running, faulted or at speed. Enclosure: NEMA 4X/12 (label: Type 4X, indoor use only). Approvals: UL listed, CE (label). Reliance manual: D2-3356-6.
Enclosure B drive, mounted with four M8 (5/16 in) bolts with washers.
Same family, same 1 HP, 380–460 V rating: 1SU41001 in the NEMA 1 vented enclosure. Also written 1SU-44001.
380–460 V AC three-phase, 2.5 A input, for a 1 HP motor with 2.1 A output.
Reliance lists the 1SU44001 as NEMA 4X/12 (not vented). The unit label reads Type 4X, indoor use only.
Yes. A four-character LED display with six membrane keys is built into the cover. The cover on this unit is cracked at one corner.
$460.99
4 in stock
$455.99
5 in stock
$93.99
10 in stock
$56.99
4 in stock
$195.99
4 in stock
$218.99
5 in stock
$290.99
16 in stock
A dental handpiece spins its bur at roughly 200,000 to 400,000 rpm on ball bearings,
Many industrial loads need torque an electric motor can’t deliver on its own, at a
Belt drives may appear simple, consisting of two wheels and a belt for power transfer.
Our team can locate, cross-reference, and source all parts.
Our team can locate, cross-reference, and source all parts.
Sort
Brand
Price
MPN
Categories