New Inventory Daily | Same Day Free Shipping

12,984 ratings on eBay See our eBay feedback →

FestoSPAU-P10R-W-Q6D-L-PNLK-PNVBA-M12UPressure Sensor with LCD Display and IO-Link, 0 to 10 bar Relative, MS4 Service Unit Flange, M12 4-Pin, IP65

Condition: New

Availability:

4 in stock

Electronic pressure sensor, 0 to 10 bar relative, MS4 service-unit flange, LCD display, IO-Link, two switchable PNP/NPN outputs, M12 4-pin, IP65.

List Price

$205.77

4 in stock

Availability

4 in stock

On the Shelf & Ready to Ship

Free Shipping

On all orders

Free Returns

No Risk, No Hassle

Also Available From:

Specifications

Key Specifications

MFR / BrandFesto
MPNSPAU-P10R-W-Q6D-L-PNLK-PNVBA-M12U
ModelSPAU-P10R-W-Q6D-L-PNLK-PNVBA-M12U / 8035304

Technical Specifications

ConditionNew
TypePressure Sensor
Base NumberSPAU-P10R
Termination TypeConnector
Output TypeTwo switching outputs PNP/NPN; analogue 0-10 V, 1-5 V or 4-20 mA; IO-Link
Pressure TypeRelative (gauge) pressure
Sensing TechnologyPiezoresistive
Connector StyleM12 x 1, 4-pin, A-coded to EN 61076-2-101
Maximum Pressure10 bar measuring range, 15 bar overload
Output Amperage100 mA per switching output
Mpn Variants8035304, SPAUP10RMS4FLPNLKPNVBAM12D, SPAU P10R MS4 F L PNLK PNVBA M12D
Additional AttributesMeasured variable: relative pressure. Measuring range 0 to 10 bar, overload 15 bar. Piezoresistive element, 12-bit ADC. Accuracy +/-1.5 % FS. Two outputs: PNP/NPN switching with IO-Link on output A; PNP/NPN or analogue 0-10 V / 1-5 V / 4-20 mA on output B. Illuminated LCD. IP65. CRC 2. UL file E322346.
MaterialHousing: PA reinforced. Keypad: TPE-O. Plug housing: nickel-plated brass.
Min Temp0 °C
SeriesSPAU
Max Temp50 °C
Ip RatingIP65
Nominal Rated Input Voltage20 to 30 V DC
Item Weight80 g (0.18 lb)
Part NumberSPAU-P10R-MS4-F-L-PNLK-PNVBA-M12D
Mounting TypeMS4 service unit flange, front panel mounting
Communication StandardIO-Link Device V1.1, COM2 38.4 kBd, port class A

Cross-References

Cross Reference 1Festo 8035304
Seller Part Number: AO2B5#6BIZDJ

Product Description

What this part is

Festo SPAU-P10R-MS4-F-L-PNLK-PNVBA-M12D, Festo order number 8035304, an electronic pressure sensor with an illuminated LCD display for compressed air and inert gases. Measured Variable: relative (gauge) pressure. Pressure Measuring Range: 0 to 10 bar. Maximum Overload Pressure: 15 bar. Method of Measurement: piezoresistive sensor element. Pneumatic Connection: flange, seated directly on an MS4 series service unit. Electrical Connection: M12x1 plug, 4 pins, A-coded to EN 61076-2-101. Degree of Protection: IP65. Product Weight: 80 g.

Decoding the designation

SPAU — Festo’s electronic pressure sensor family for compressed air and inert gases.

P10R — relative pressure, measuring range 0 to 10 bar.

MS4 — flange pneumatic connection sized for the MS4 series air preparation unit.

F — front panel mounting provision, 34 x 61 mm cut-out.

L — illuminated LCD display with three-button operation.

PNLK — output A: a switching output selectable as PNP or NPN, carrying IO-Link communication on the same pin.

PNVBA — output B: selectable as a second PNP or NPN switching output, or as an analogue voltage or current output.

M12D — M12x1 plug, four pins, A-coded.

What these specs mean in practice

Accuracy: ±1.5 % FS at room temperature. Repetition Accuracy: ±0.3 % FS. Temperature Coefficient: ±0.05 % FS/K. ADC Resolution: 12 bit. Rise Time: 3 ms. A 12-bit conversion over a 10 bar span resolves to roughly 2.5 mbar, which is why the same sensor covers coarse supply-pressure monitoring and fine leak-rate work.

Operating Voltage: 20 to 30 V DC. Idle Current: typically 35 mA. Maximum Output Current: 100 mA per switching output. Voltage Drop: max 1.6 V. Short-Circuit Protection: yes. Reverse Polarity Protection: on all electrical connections. Ready-State Delay: typically 160 ms.

Analogue Output Options: 0 to 10 V, 1 to 5 V, or 4 to 20 mA. Maximum Load Resistance, Current Output: 500 ohm. Minimum Load Resistance, Voltage Output: 10 kilohm.

Switching Element Function: normally open or normally closed, switchable. Switching Function: freely programmable across three modes — threshold value comparator for a single set point, window comparator for a pressure band, and automatic difference monitoring, which learns a reference pressure and switches when the line drifts outside a set band. That third mode is what turns the sensor into a leak detector on a clamped or sealed volume.

Threshold Value Setting Range: 0 to 100 % FS. Hysteresis Setting Range: 0 to 90 % FS. Displayable Units: bar, kPa, MPa, psi, mmHg, inchHg, inchH2O, kgf/cm².

IO-Link Protocol Version: Device V1.1. Profile: Smart Sensor. Communication Mode: COM2, 38.4 kBd. Port Class: A. Process Data Width In: 2 byte, carrying a 14-bit pressure value and a 2-bit monitoring flag. Minimum Cycle Time: 3 ms. SIO mode is supported, so the same sensor runs as a plain switching sensor on an ordinary digital input.

Certification: UL and cUL listed, file E322346, to UL 61010-1 and CAN/CSA C22.2 No. 61010-1. RCM compliance mark. CE marking to the EU EMC and RoHS directives.

Operating limits and media

Operating Medium: compressed air to ISO 8573-1:2010 [7:4:4], and inert gases. Operation with oil lubrication is possible. Temperature of Medium: 0 to 50 °C. Ambient Temperature: 0 to 50 °C. Storage Temperature: −20 to +80 °C. Corrosion Resistance Class: CRC 2, moderate corrosion stress.

Shock Resistance: 30 g acceleration at 11 ms half-sine to EN 60068-2. Vibration Resistance: 0.35 mm amplitude from 10 to 60 Hz, 5 g from 60 to 150 Hz.

Mounting data

Type of Mounting: on a service unit. Mounting Position: any. Front Panel Cut-Out: 34 x 61 mm. Maximum Tightening Torque, service-unit mounting: 1 Nm. Maximum Tightening Torque, M12 plug: 0.5 Nm. Maximum Tightening Torque, front panel screws: 0.7 Nm, M3. Maximum Cable Length: 30 m, or 20 m in IO-Link mode.

Quantity and configuration

Unit Quantity: 1 Pc. Sensor only.

Interchange guidance

SPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D is the identical sensor on the larger MS6 service-unit flange. SPAU-P10R-W-Q6D-L-PNLK-PNVBA-M12U carries the same electronics with wall mounting and a QS push-in fitting, so it suits a free-standing line rather than a service unit. Measuring-range variants on the same body run P025, P05, P1, P2, P6, P12 and P16 for pressure and V025, V05, V1, B2 and B11 for vacuum and combined ranges — the range code is the only difference, so a P6 body will not read above 6 bar and a P16 body gives coarser resolution over the same 10 bar span.

You May Also Like

Electronics 362AZ-P Shot Flow Controller 362AZP 362A PLC Module
362AZ-P

$305.20

6 in stock

Add to cart
Servo Feed-Drive Power Board for Simodrive 610 Drive Chassis
6SC6190-OFB00

$132.49

1 in stock

Add to cart
Alpha Series Single-Axis Servo Amplifier Module SVM1-20, 283-325 VDC Bus, 20 A Class
A06B-6096-H102

$479.93

5 in stock

Add to cart

Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

News

Excess MRO Inventory Depreciating on Your Shelf

The dead stock on your shop floor is not an

MRO Parts Fulfillment. What Fast Really Means

A shipping cutoff banner measures a vendor’s dock. It tells

Additional Resources

Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Get In Touch
Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Get In Touch

Sort

Brand

Price

MPN

Categories

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.