Motor Starters vs. Contactors vs. Overload Relays: What Each One Does and Why You Need All Three
When a motor stops running, the first instinct is to find the part that looks
Availability:
4 in stock
Electronic pressure sensor, 0 to 10 bar relative, MS4 service-unit flange, LCD display, IO-Link, two switchable PNP/NPN outputs, M12 4-pin, IP65.
List Price
$205.77
4 in stock

4 in stock
On the Shelf & Ready to Ship
On all orders

No Risk, No Hassle
Also Available From:
| MFR / Brand | Festo |
|---|---|
| MPN | SPAU-P10R-W-Q6D-L-PNLK-PNVBA-M12U |
| Model | SPAU-P10R-W-Q6D-L-PNLK-PNVBA-M12U / 8035304 |
| Condition | New |
|---|---|
| Type | Pressure Sensor |
| Base Number | SPAU-P10R |
| Termination Type | Connector |
| Output Type | Two switching outputs PNP/NPN; analogue 0-10 V, 1-5 V or 4-20 mA; IO-Link |
| Pressure Type | Relative (gauge) pressure |
| Sensing Technology | Piezoresistive |
| Connector Style | M12 x 1, 4-pin, A-coded to EN 61076-2-101 |
| Maximum Pressure | 10 bar measuring range, 15 bar overload |
| Output Amperage | 100 mA per switching output |
| Mpn Variants | 8035304, SPAUP10RMS4FLPNLKPNVBAM12D, SPAU P10R MS4 F L PNLK PNVBA M12D |
| Additional Attributes | Measured variable: relative pressure. Measuring range 0 to 10 bar, overload 15 bar. Piezoresistive element, 12-bit ADC. Accuracy +/-1.5 % FS. Two outputs: PNP/NPN switching with IO-Link on output A; PNP/NPN or analogue 0-10 V / 1-5 V / 4-20 mA on output B. Illuminated LCD. IP65. CRC 2. UL file E322346. |
| Material | Housing: PA reinforced. Keypad: TPE-O. Plug housing: nickel-plated brass. |
| Min Temp | 0 °C |
| Series | SPAU |
| Max Temp | 50 °C |
| Ip Rating | IP65 |
| Nominal Rated Input Voltage | 20 to 30 V DC |
| Item Weight | 80 g (0.18 lb) |
| Part Number | SPAU-P10R-MS4-F-L-PNLK-PNVBA-M12D |
| Mounting Type | MS4 service unit flange, front panel mounting |
| Communication Standard | IO-Link Device V1.1, COM2 38.4 kBd, port class A |
| Cross Reference 1 | Festo 8035304 |
|---|
Festo SPAU-P10R-MS4-F-L-PNLK-PNVBA-M12D, Festo order number 8035304, an electronic pressure sensor with an illuminated LCD display for compressed air and inert gases. Measured Variable: relative (gauge) pressure. Pressure Measuring Range: 0 to 10 bar. Maximum Overload Pressure: 15 bar. Method of Measurement: piezoresistive sensor element. Pneumatic Connection: flange, seated directly on an MS4 series service unit. Electrical Connection: M12x1 plug, 4 pins, A-coded to EN 61076-2-101. Degree of Protection: IP65. Product Weight: 80 g.
SPAU — Festo’s electronic pressure sensor family for compressed air and inert gases.
P10R — relative pressure, measuring range 0 to 10 bar.
MS4 — flange pneumatic connection sized for the MS4 series air preparation unit.
F — front panel mounting provision, 34 x 61 mm cut-out.
L — illuminated LCD display with three-button operation.
PNLK — output A: a switching output selectable as PNP or NPN, carrying IO-Link communication on the same pin.
PNVBA — output B: selectable as a second PNP or NPN switching output, or as an analogue voltage or current output.
M12D — M12x1 plug, four pins, A-coded.
Accuracy: ±1.5 % FS at room temperature. Repetition Accuracy: ±0.3 % FS. Temperature Coefficient: ±0.05 % FS/K. ADC Resolution: 12 bit. Rise Time: 3 ms. A 12-bit conversion over a 10 bar span resolves to roughly 2.5 mbar, which is why the same sensor covers coarse supply-pressure monitoring and fine leak-rate work.
Operating Voltage: 20 to 30 V DC. Idle Current: typically 35 mA. Maximum Output Current: 100 mA per switching output. Voltage Drop: max 1.6 V. Short-Circuit Protection: yes. Reverse Polarity Protection: on all electrical connections. Ready-State Delay: typically 160 ms.
Analogue Output Options: 0 to 10 V, 1 to 5 V, or 4 to 20 mA. Maximum Load Resistance, Current Output: 500 ohm. Minimum Load Resistance, Voltage Output: 10 kilohm.
Switching Element Function: normally open or normally closed, switchable. Switching Function: freely programmable across three modes — threshold value comparator for a single set point, window comparator for a pressure band, and automatic difference monitoring, which learns a reference pressure and switches when the line drifts outside a set band. That third mode is what turns the sensor into a leak detector on a clamped or sealed volume.
Threshold Value Setting Range: 0 to 100 % FS. Hysteresis Setting Range: 0 to 90 % FS. Displayable Units: bar, kPa, MPa, psi, mmHg, inchHg, inchH2O, kgf/cm².
IO-Link Protocol Version: Device V1.1. Profile: Smart Sensor. Communication Mode: COM2, 38.4 kBd. Port Class: A. Process Data Width In: 2 byte, carrying a 14-bit pressure value and a 2-bit monitoring flag. Minimum Cycle Time: 3 ms. SIO mode is supported, so the same sensor runs as a plain switching sensor on an ordinary digital input.
Certification: UL and cUL listed, file E322346, to UL 61010-1 and CAN/CSA C22.2 No. 61010-1. RCM compliance mark. CE marking to the EU EMC and RoHS directives.
Operating Medium: compressed air to ISO 8573-1:2010 [7:4:4], and inert gases. Operation with oil lubrication is possible. Temperature of Medium: 0 to 50 °C. Ambient Temperature: 0 to 50 °C. Storage Temperature: −20 to +80 °C. Corrosion Resistance Class: CRC 2, moderate corrosion stress.
Shock Resistance: 30 g acceleration at 11 ms half-sine to EN 60068-2. Vibration Resistance: 0.35 mm amplitude from 10 to 60 Hz, 5 g from 60 to 150 Hz.
Type of Mounting: on a service unit. Mounting Position: any. Front Panel Cut-Out: 34 x 61 mm. Maximum Tightening Torque, service-unit mounting: 1 Nm. Maximum Tightening Torque, M12 plug: 0.5 Nm. Maximum Tightening Torque, front panel screws: 0.7 Nm, M3. Maximum Cable Length: 30 m, or 20 m in IO-Link mode.
Unit Quantity: 1 Pc. Sensor only.
SPAU-P10R-MS6-F-L-PNLK-PNVBA-M12D is the identical sensor on the larger MS6 service-unit flange. SPAU-P10R-W-Q6D-L-PNLK-PNVBA-M12U carries the same electronics with wall mounting and a QS push-in fitting, so it suits a free-standing line rather than a service unit. Measuring-range variants on the same body run P025, P05, P1, P2, P6, P12 and P16 for pressure and V025, V05, V1, B2 and B11 for vacuum and combined ranges — the range code is the only difference, so a P6 body will not read above 6 bar and a P16 body gives coarser resolution over the same 10 bar span.
$305.20
6 in stock
$132.49
1 in stock
$479.93
5 in stock
$417.66
4 in stock
$288.34
5 in stock
$1,288.65
5 in stock
$479.93
5 in stock
$105.56
15 in stock
A shipping cutoff banner measures a vendor’s dock. It tells
When a motor stops running, the first instinct is to find the part that looks
From Caligula’s luxury fleet to modern factories, this is the story of how a single
When sourcing a replacement bearing, you will often find both Timken and SKF options for
Our team can locate, cross-reference, and source all parts.
Our team can locate, cross-reference, and source all parts.
Sort
Brand
Price
MPN
Categories