New Inventory Daily | Same Day Free Shipping

13k+ reviews

Carlo GavazziSingle-Phase 1-Module DIN-Rail Energy Meter, 230 V L-N, 5(45) A Direct, RS485 Modbus, Bidirectional MID Class B

Condition: Used

Availability:

3 in stock

Single-phase DIN-rail kWh meter one module wide, 230 V line-to-neutral, direct connection rated 32 A continuous and 45 A maximum. RS485 Modbus RTU output, separate import and export registers, MID certified for billing. Sold as 1 piece.

Same day shipment

List Price

$67.98

3 in stock

Prefer eBay? Buy this item on our store (opens in a new tab)

Small green outline icon of a shipping box with a clock, indicating delivery time
Availability

3 in stock

On the Shelf & Ready to Ship

Green shield badge reading "Same-Day Shipping" with box and delivery truck icons
Free Shipping

On all orders

Green shield icon with box and arrow graphic labeled "Free Returns"
Free Returns

No Risk, No Hassle

Specifications

Key Specifications

MFR / BrandCarlo Gavazzi
ModelEM111 DIN AV8 1 X S1 PF B

Technical Specifications

Base NumberEM111-DIN
Industry Termsenergy analyzer; energy analyser; kWh meter; Modbus energy meter; sub-meter; DIN rail power meter; MID meter
Common MisspellingsCarlo Gavazi; Carlogavazzi; Carlo-Gavazi; EM111 DIN AV8
Application TypesTenant sub-metering; cost allocation; dual-tariff billing; Modbus SCADA and BMS energy monitoring; narrow panel retrofits
Output Amperage5(45) A measuring range, 32 A rated primary, direct connection
Mpn VariantsEM111DINAV81XS1PFB; EM111-DIN AV8 1 X S1 PF B; EM111DIN.AV8.1.X.S1.PF.B; EM111-DIN.AV8.1.X.S1.PFB
Nominal Rated Input Voltage230 V AC L-N
Part NumberEM111-DIN.AV8.1.X.S1.PF.B
Mounting TypeDIN rail
Communication StandardRS485 Modbus RTU, 9.6 to 115.2 kbaud
Seller Part Number: AG1B1#SD3TBP

Product Description

What this part is

A Carlo Gavazzi EM111 single-phase energy analyser in a 1-module DIN-rail housing — the narrowest meter in the range at 17.5 mm wide. It meters active and reactive energy on a 230 V line-to-neutral circuit with the load current passing directly through the meter, and reports over RS485 Modbus RTU. Backlit 7-digit LCD with a touch keypad.

Decoding the designation

The order code EM111-DIN.AV8.1.X.S1.PF.B reads as model, range, system, power supply, output, option, measurement.

EM111-DIN – single-phase analyser, DIN-rail housing, 1 module.

AV8 – 230 V L-N AC, 5(45) A direct connection, rated 32 A primary.

1 – 1-phase, 2-wire system.

X – self powered from the measured voltage, no auxiliary supply.

S1 – RS485 Modbus RTU port (M1 is M-Bus, O1 a pulse output).

PF – certified to the MID Directive, Modules B and D, usable for fiscal metrology.

B – bidirectional: imported and exported energy on separate registers, with only the total positive register MID certified.

What these specs mean in practice

Rated Primary Current: 32 A. Maximum Current: 45 A, which Carlo Gavazzi allows with a 6 mm² conductor where local rules and the terminals permit. The B measurement option separates import from export and lights a fixed orange LED when the current direction is reversed, which flags a backwards direct connection. At one DIN module it is narrower than the 2-module EM112, and rated 45 A direct against 100 A for the EM112.

Published specifications

System: 1-phase, 2-wire. Nominal Voltage: 230 V L-N AC, −30% +20%. Current: Ib 5 A, Imax 45 A, Imin 0.25 A, direct connection (32 A rated primary). Start-up Current: 20 mA. Start-up Voltage: 161 V L-N. Active Energy: Class 1 per EN62053-21, Class B per EN50470-3. Reactive Energy: Class 2 per EN62053-23. Current/Voltage Accuracy: ±0.5% of reading. Performance: IEC/EN61557-12 class 1 active power, class 2 active energy.

Registers: kWh and kvarh imported and exported separately, kWh+ on two tariffs. Instantaneous Values: kW, kvar, V, A, PF, Hz, kW demand and demand peak. Communication: RS485 Modbus RTU slave, 9.6 / 19.2 / 38.4 / 57.6 / 115.2 kbaud, address 1 to 247, up to 247 transceivers per bus, 1 s data refresh. Default Modbus Address: 01. Default Baud Rate: 9.6 kbaud. Default Parity: none. Maximum RS485 Run Without Repeater: 1000 m. Demand Integration Time: 1 to 30 minutes, default 1 minute. Digital Input: 1, volt-free contact, for tariff switching. Front LED: 1000 imp/kWh (AV8). Sampling: 4096 samples/s.

Insulation: 4000 V AC RMS for 1 minute; overvoltage category III. Operating Temperature: −25 to +55 °C (PF option, standard suffixes). Protection: IP51 front, IP20 terminals. Power Consumption: ≤1.0 W, ≤8 VA. Weight: approx. 80 g.

Mounting data

Housing: 17.5 x 63 x 91.5 mm (W x D x H), 1 DIN module, PBT self-extinguishing UL 94 V-0. Measuring terminals: 6 mm² max, 1.1 Nm. Other terminals: 1.5 mm², 0.4 Nm.

Quantity and configuration

Unit Quantity: 1 Pc. Sealing covers are part of the standard product.

Interchange guidance

The suffixes are the part number. AV5 is the 5(6) A CT-input version and MV5 the 333 mV current-sensor version, both for use with external sensors rather than direct connection. AV7 is the 120 V variant. M1 and O1 replace the RS485 port with M-Bus or a pulse output. The .PF.A version sums both current directions into one certified register. The 2-DIN EM112 covers 100 A direct and the 3-DIN EM330/EM340 are three-phase — related models, not substitutes.

You May Also Like

Power Switch Board — 350280 Rev. C Printed Circuit Board
302224

$417.66

4 in stock

Add to cart
Exposed Linear Encoder — LIDA Series, ID 233042-13

$160.00

5 in stock

Add to cart
Shot Flow Controller — Shot Peening and Blast Media Flow Control
362AZ-P

$305.20

6 in stock

Add to cart

Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Assortment of MRO parts including motor, bearing, gears, cylinder and valve

News

Selling an MRO Storeroom in One Lot

Most plants clear a storeroom one part number at a

Selling Surplus Fanuc Boards and Servo Amplifiers

When a CNC machine or a robot leaves the plant,

Additional Resources

Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Get In Touch
Need help finding the right part?

Our team can locate, cross-reference, and source all parts.

Get In Touch

Sort

Brand

Price

MPN

Categories

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.