Eaton Vickers DG5S-8-2A-T-M-FPA5W-B5-30 pilot operated directional valve, NFPA D08 / ISO 4401-08, 210 bar (3000 psi), with DG4V-3S-2A-M-FPA5W-B5-60 pilot.
List Price
$764.97

1 in stock
On the Shelf & Ready to Ship
On all orders

No Risk, No Hassle
| MFR / Brand | Eaton |
|---|---|
| MPN | DG5S-8-2A-T-M-FPA5W-B5-30 |
| Model | DG5S82ATMFPA5WB530 |
| Valve Operation | Solenoid |
|---|---|
| Base Number | DG5S-8 |
| Industry Terms | 4-way directional valve, two-stage directional valve, D08 valve, CETOP 8, NG25, solenoid pilot valve |
| Common Misspellings | DG5S8, DG5S-8-2A, Vicker DG5S, DG55-8 |
| Application Types | Industrial hydraulic circuits, cylinder and hydraulic motor direction control |
| Coil Voltage | 110V AC 50 Hz / 120V AC 60 Hz |
| Mpn Variants | DG5S-8-2A-T-M-FPA5W-B5-30, DG5S82ATMFPA5WB530, DG4V-3S-2A-M-FPA5W-B5-60, DG4V3S2AMFPA5WB560, 02-318039, DG5S-8-2A-T-M-FPA5W-B5-30/DG4V-3S-2A-M-FPA5W-B5-60 |
| Additional Attributes | Mounting Interface: NFPA D08 / ISO 4401-08; Spool: type 2, spring offset to A; Pilot Drain: internal; Electrical: five-pin connector, 1/2 NPT housing; Pilot Tank Rating: 100 bar (1450 psi); Design: 30 |
| Series | DG5S-8 |
| Type | Solenoid Pilot Operated Directional Control Valve |
Eaton Vickers DG5S-8-2A-T-M-FPA5W-B5-30 is a two-stage, solenoid controlled, pilot operated four-way directional valve with its integrally mounted DG4V-3S-2A-M-FPA5W-B5-60 pilot valve. Assembly number 02-318039. Single solenoid, spring offset, subplate mounted on an NFPA D08 / ISO 4401-08 interface. One valve assembly.
DG5S — directional control valve, subplate mounted, solenoid controlled and pilot operated, sliding spool rated 210 bar (3000 psi).
8 — NFPA D08 (ISO 4401-08) mounting interface.
2 — spool type 2, closed to tank at all ports in the center condition.
A — spring offset to the A port; single solenoid.
T — internal pilot drain.
M — electrical options and features flag.
FPA5W — flying-lead coil (F) with a five-pin connector (PA5) in a 1/2 NPT wiring housing (W).
B — coil for 110V AC 50 Hz / 120V AC 60 Hz.
5 — pilot valve tank pressure rating 100 bar (1450 psi), DG4V3S-60 pilot.
30 — design number for the DG4V3S-60 standard performance pilot valve.
Maximum Operating Pressure: 210 bar (3000 psi).
Recommended Flow: to 170 L/min (45 USgpm).
Pilot Tank Line Pressure: 100 bar (1450 psi).
Coil Voltage: 110V AC 50 Hz / 120V AC 60 Hz.
Valve Operation: solenoid, pilot operated.
Electrical Connection: five-pin connector in 1/2 NPT wiring housing.
Country of Origin: United States.
Mounting Interface: NFPA D08 / ISO 4401-08 / ANSI B93.7 subplate or manifold. Pilot Drain: internal.
Valve DG5S-8-2A-T-M-FPA5W-B5-30 with pilot valve DG4V-3S-2A-M-FPA5W-B5-60, assembly number 02-318039. Compressed forms: DG5S82ATMFPA5WB530 and DG4V3S2AMFPA5WB560. Source: Vickers catalog 591.
NFPA D08 / ISO 4401-08 / ANSI B93.7 subplate or manifold mounting.
Maximum operating pressure 210 bar (3000 psi), with recommended flow to 170 L/min (45 USgpm).
Coil code B: 110V AC 50 Hz / 120V AC 60 Hz, with a five-pin connector in a 1/2 NPT wiring housing.
$59.36
1 in stock
$243.22
1 in stock
$1,326.31
1 in stock
$59.36
1 in stock
$108.21
1 in stock
$52.96
1 in stock
$33.09
1 in stock
If you pulled a bearing off general industrial equipment at random, there’s a good chance
A faster way to search our bearing inventory Today we’re launching the Central Surplus Bearing
When an HMI panel goes dark or a PLC module stops communicating, the machine it
Our team can locate, cross-reference, and source all parts.
Our team can locate, cross-reference, and source all parts.
Sort
Brand
Price
MPN
Categories